Supporting procedures
Configuring alarm severity
....................................................................................................................................................................................................................................
Configuring Alarm Severity Using the 1354 RM-PhM
You can change the default alarm severity for an alarm condition on a specific entity (for
example a port) or for all entities of the same type. You can configure the alarm severity
using the EMS or web interface. This capability is not available in the CLI.
Configuring Alarm Severity for All Entities of the Same Type
...................................................................................................................................................................................................
1
To configure the alarm severity for all entities of the same type, go to the Topology View
and select the NE or NEs on which you want to change the alarm severity.
Note: If you do not explicitly select any NEs, the EMS will select all NEs in the
network for configuration. In this case, the EMS will retrieve alarm configuration data
for all of the NEs in the network, which may take a significant amount of time.
...................................................................................................................................................................................................
2
Select
The EMS retrieves the alarm severity configuration for the selected NEs. This may take
several minutes. The Alarm Severity Configuration window is displayed, listing the
selected NEs.
...................................................................................................................................................................................................
Click on the Display object type alarm severity assignments icon.
3
A dialog listing the entity types is displayed.
...................................................................................................................................................................................................
4
Select the entity type for which you want to change the alarm severity.
A list of condition types applicable to the selected entity is displayed.
...................................................................................................................................................................................................
5
Double click on the condition type you want to change.
A dialog is displayed showing the current alarm severity override setting.
...................................................................................................................................................................................................
Change the severity as desired and select
6
E
N D
O F
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Admin
>
NE Alarm Severity Configuration
S T E P S
Configuring Alarm Severity Using the 1354 RM-PhM
.
Apply
.
3-7