Trouble-clearing procedures
EQPT
....................................................................................................................................................................................................................................
EQPT (Card Failure - Device)
Severity
Service affecting?
Applicability
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step. If
this condition is raised against the user panel or a fan tray, then after each step warm reset
the active Equipment Controller.
...................................................................................................................................................................................................
Perform a warm reset of the card.
1
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset of the card.
2
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Critical
Yes
112SA1L, 112SCA1, 112SCX10, 112SX10L, 11DPE12E,
11DPM12, 11STAR1, 11STMM10, 11STGE12, 43SCX4,
43STA1P, 43STX4, 43STX4P, 4DPA2, 4DPA4, A2325A, AHPHG,
AHPLG, ALPHG, ALPFGT, AM2017B, AM2125A, AM2125B,
AM2318A, AM2325B, CWR, FAN, MESH4, MVAC, OPS, OSC,
OSCT, PF, RA2P, SFC, SFD, SVAC, USRPNL, WR, WTOCM
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
config card
Select the card, click the
config card
Select the card, click the
3-19).
card type shelf slot
reset warm
tab, select
Reboot
card_type shelf slot
reset cold
tab, select
Reboot
EQPT (Card Failure - Device)
>
.
Warm Reboot
Submit
>
.
Cold Reboot
Submit
2-73