Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 307

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
CONTR-OUT
....................................................................................................................................................................................................................................
CONTR-OUT (Port degrade - wavelength tracker detection
failure)
The Wavelength Tracker on this card has detected an internal DSP fault. The Wavelength
Tracker information generated may be inaccurate. Channels may be declared absent
and/or detected channel powers for this channel instance may not accurately represent the
actual channel power.
Severity
Service affecting?
Applicability
Note: Until this alarm is cleared, wavelength tracking information for the detect
points on the card are invalid.
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Perform a warm reset of the card.
1
CLI
WEBUI
...................................................................................................................................................................................................
2
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Minor
No
AHPHG, AHPLG, ALPHG, ALPFGT, AM2017B, AM2125A,
AM2125B, AM2325B, CWR, OSCT
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
config card
Select the card, click the
config card
CONTR-OUT (Port degrade - wavelength tracker detection
3-19).
card type shelf slot
reset warm
Reboot
tab, select
card_type shelf slot
reset cold
Warm Reboot
>
Submit
.
failure)