Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 525

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
PWRSUSP
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
If checking the add path topology for clean connections between packs did not resolve the
2
issue, try triggering an egress adjustment at the LD Line port of the egress line to which
the CWR8 Sig port connects.
...................................................................................................................................................................................................
Perform a warm reset of the CWR8 pack.
3
CLI
WEBUI
...................................................................................................................................................................................................
4
Perform a cold reset of the CWR8 pack.
CLI
WEBUI
...................................................................................................................................................................................................
Replace the CWR8 pack.
5
...................................................................................................................................................................................................
Check whether the WT powers of the alarmed channels are missing at the LD Line port of
6
the egress line that the CWR8 Sig port connects to.
If...
the WT powers of the alarmed channels are
missing
the WT powers of the alarmed channels are
not missing
...................................................................................................................................................................................................
Perform a warm reset of the egress line LD pack.
7
...................................................................................................................................................................................................
8
Perform a cold reset of the egress line LD pack.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
config card card type shelf slot reset warm
Select the card, click the Reboot tab, select
config card card type shelf slot reset cold
Select the card, click the Reboot tab, select
PWRSUSP-CWR8 (Power management suspended)
Warm Reboot
Cold Reboot
Then...
determine using the PhM lightpath trace or
other method whether excessive loss exists
between the CWR8 Sig port and the egress
line.
determine if the fiber is kinked along this path
and fix the problem. If loss is excessive and
the fiber is not kinked try to clean connections
between the CWR8 Sig port and the LD Line
port.
>
Submit
.
>
Submit
.