Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 599

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
VCGSSF
....................................................................................................................................................................................................................................
Corrective Action
...................................................................................................................................................................................................
Verify that the time slot information on the 11STMM10 line port and ODU1 are correctly
1
provisioned on each end of the optical link. If not, use the following CLI commands to
ensure timeslots are provisioned the same:
Config interface 11STMM10 shelf slot/C{1-10} 1gbe timeslot
line
Config interface 11stmm10 shelf slot/C{1-10} 1gbe timeslot vts
0 or 1, 4, 7, 10, 13, 16, 19, 22, 25, 28, 31, 34, 37, 40, 43, 46
E
N D
O F
...................................................................................................................................................................................................
VOLTAGEHIGH
VOLTAGEHIGH [High input voltage defect]
The voltage level of the external DC supply is high. This alarm is raised if there is too
much voltage going to the breaker feed or the voltage is above the threshold. This could
be due to a problem with the power feed to the breaker card.
Severity
Service affecting?
Applicability
At the end of each step wait to see if the fault clears. If it does not, go to the next step.
...................................................................................................................................................................................................
Using a DC voltmeter, measure the power going to the shelf and verify that it is within
1
the accepted limits for proper operation (-48 to -52 volts).
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
1 - 4
S T E P S
Critical
No
112SA1L, 112SCA1, 112SCX10, 112SX10L, 11DPE12E,
11DPM12, 11STAR1, 11STMM10, 11STGE12, 43SCX4,
43STA1P, 43STX4, 43STX4P, 4DPA2, 4DPA4, AHPHG, AHPLG,
ALPHG, ALPFGT, AM2017B, AM2125A, AM2125B, CWR,
Equipment Controller, FLC, MESH4, MT0C, MVAC, OPS,
OSCT, RA2P, SVAC, USRPNL, WR, WTOCM