Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 381

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
LINKDOWN
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Perform a cold reset on the card that is the source of the Ethernet signal.
7
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset on the card where the LINKDOWN condition is raised.
8
Note: Refer to Caution at the beginning of this procedure.
...................................................................................................................................................................................................
9
Reseat the card that is the source of the Ethernet signal.
...................................................................................................................................................................................................
Reseat the card where the LINKDOWN condition is present
10
...................................................................................................................................................................................................
Replace the card that is the source of the Ethernet signal.
11
...................................................................................................................................................................................................
Replace the card where the LINKDOWN condition is present
12
E
N D
O F
...................................................................................................................................................................................................
LINKUP
LINKUP (Link Up)
The LINKUP autonomous message is issued after serial connection is established on the
CIT port.
Severity
Service affecting?
Applicability
No corrective action is required. This is a normal message.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
config card
Select the card, click the
S T E P S
TC
No
FAN
card type shelf slot
reset cold
tab, select
Reboot
LINKDOWN (Link down)
>
.
Cold Reboot
Submit
2-131