Trouble-clearing procedures
SSFODU
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
If cleaning the fiber does not clear the problem, replace the fiber.
8
...................................................................................................................................................................................................
9
If the problem is detected on the client port of 11STAR1 OT, and the power level is
within the operating range, check for pluggable module alarms.
...................................................................................................................................................................................................
Replace the pluggable module.
10
E
N D
O F
...................................................................................................................................................................................................
SSFODUEGR
SSFODUEGR (Egress Signal Server Failure - ODU)
The OT port has detected a Server Signal Failure at the ODUk level exiting the client
port. Conditions that can cause an SSFODU are:
• LOS-P (Loss of Signal – OTU)
• LOF (Loss of Frame – OTU)
• LOM (Loss of Multiframe – OTU)
• ODU-AIS
These conditions may be caused by the following reasons:
• A misconnected, damaged or dirty fiber on the trail between the local OTUk receive
port and the far end transmitter
• OTS/OMS layer failure on the OCh trail
• The received power may not be within the acceptable range on the Far end input
Severity
Service affecting?
Applicability
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
S T E P S
NR
No
43STX4, 43STX4P
SSFODU (Server Signal Failure - ODU)
2-297