Trouble-clearing procedures
....................................................................................................................................................................................................................................
OPR-OUT
OPR-OUT (Outgoing Channel Optical Power Out of Range)
The OPR-OUT condition is raised on cards with a Wavelength Tracker detect point when
the power of the outgoing channel is outside of the provisioned power range. This alarm
may be caused by the introduction of more or less attenuation in the fiber, or by an
amplifier adjust that may have occurred elsewhere in the network, due to fiber repair
activity or network adjustments such as adding or deleting a node.
Severity
Service affecting?
Applicability
Corrective Action
Refer to
....................................................................................................................................................................................................................................
2-238
Minor
No
A2325A, AHPHG, AHPLG, ALPHG, AM2017B, AM2125A,
AM2125B, AM2325B, CWR8
"OPRTX (Channel Power Unstable)" (p.
OPR-OUT (Outgoing Channel Optical Power Out of Range)
2-239).
8DG60888CAAA Release 3.6.0 and 3.6.1