Trouble-clearing procedures
PWRADJREQ
....................................................................................................................................................................................................................................
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Perform a power adjust operation at the ingress amplifier card or the ALPHG card that
1
has raised the PWRADJREQ alarm.
CLI
...................................................................................................................................................................................................
2
If...
the adjustment is successful,
the adjustment fails,
...................................................................................................................................................................................................
Follow the appropriate procedures in the Alcatel-Lucent User Provisioning Guide to
3
validate the set parameters of the network per the Network Plan.
E
N D
O F
...................................................................................................................................................................................................
PWRMARGIN
PWRMARGIN (Power Adjust Loss Margin Exceeded)
This condition is raised as a result of the gain, required to increase the power level at the
ingress port of an LD amplifier, being close to the maximum value as set by the
Engineering and Planning Tool (EPT). Without the ability to increase the gain any further,
the repair margin has been compromised and any additional loss would result in
power-adjust alarms.
Severity
Service affecting?
Applicability
....................................................................................................................................................................................................................................
2-266
config powermgmt ingress | egress shelf slot
S T E P S
Minor
No
A2325A, AHPHG, AHPLG, ALPHG, ALPFGT, AM2017B,
AM2125A, AM2125B, AM2325B, OSCT
PWRADJREQ (Power Adjust Required)
Then...
the PWRADJREQ alarm will be cleared.
Continue with
Step
3.
the PWRADJFAIL alarm will appear. Proceed
to
"PWRADJFAIL" (p.
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
2-257).