Trouble-clearing procedures
LOS-P
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
If power level is low on the DWDM facing port, identify the associated OCh trail and
2
verify the power levels along the OCh trail.
...................................................................................................................................................................................................
Identify the farthest upstream point relative to the far end OTUk port at which power
3
level falls within the expected range.
...................................................................................................................................................................................................
4
Check the alarms/conditions on the node located in
upstream from point identified in
...................................................................................................................................................................................................
Correct the problem identified in
5
...................................................................................................................................................................................................
6
If all power levels along the OCh trails fall within the target range, locate the fiber
connected directly to receiver of the port which detects SSF condition.
...................................................................................................................................................................................................
Clean the fiber.
7
...................................................................................................................................................................................................
8
If cleaning the fiber does not clear the problem, replace the fiber.
...................................................................................................................................................................................................
If the problem is detected on the client port of 11STAR1 OT, and the power level is
9
within the operating range, check for pluggable module alarms.
...................................................................................................................................................................................................
10
Replace the pluggable module.
E
N D
O F
...................................................................................................................................................................................................
LPBKLINE
LPBKLINE (Line [Facility] Loopback Active)
A line loopback is active on the specified port. Loopbacks are user-initiated and may only
be cleared by manually removing them from the port.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
S T E P S
Step 3
Step
4.
Step
4.
LOS-P (Incoming Payload LOS)
or the node immediately