Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 306

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
CONTR
....................................................................................................................................................................................................................................
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Perform a warm reset of the card.
CLI
WEBUI
...................................................................................................................................................................................................
2
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
3
Reseat the card. Refer to
...................................................................................................................................................................................................
Replace the card. Refer to
4
and repair process in the Customer and Product Support guide to return the faulty card to
an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
CONTR-OUT
....................................................................................................................................................................................................................................
2-56
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
config card
Select the card, click the
config card
Select the card, click the
"Reseating a Card" (p.
"Replacing System Components" (p.
S T E P S
CONTR (Port degrade - wavelength tracker failure)
3-19).
card type shelf slot
reset warm
Reboot
tab, select
card_type shelf slot
reset cold
Reboot
tab, select
3-19).
Warm Reboot
>
Submit
.
Cold Reboot
>
Submit
.
3-20). Follow the return
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents