Trouble-clearing procedures
MOD
....................................................................................................................................................................................................................................
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Perform a warm reset on the card where the MOD condition is raised.
CLI
WEBUI
...................................................................................................................................................................................................
2
Do the following for MVAC, SVAC or VA ports:
1. Verify that the fiber patch cable(s) between the source optical port and the encoder
port input are not kinked or bent at a tight radius, which could increase optical
insertion loss between components. If any are kinked or bent, gently correct, and then
wait 5 minutes before proceeding to the next step.
2. Verify that the fiber patch cable(s) between the source optical port and the encoder
port input are not dirty or damaged (this step is service affecting). Verifying and
cleaning the fiber connectors requires disconnecting the output of the source optical
port (for example, the L1 port of a 4DPA4 pack). After cleaning or patch cable
replacement, wait 5 minutes to see if the alarm clears.
3. Verify that the output power from the source optical port is as expected given the
interface type. Measuring with an optical power meter is service affecting, as it
requires disconnecting the output of the source optical port. If necessary, replace the
source optical transmitter and wait 5 minutes to see if the alarm clears.
...................................................................................................................................................................................................
Perform a cold reset of the card.
3
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
....................................................................................................................................................................................................................................
2-196
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
config card
Select the card, click the
config card
Select the card, click the
MOD (Card degrade - Wavelength Tracker Channel ID
3-19).
card_type shelf slot
reset warm
Reboot
tab, select
card_type shelf slot
reset cold
tab, select
Reboot
Warm Reboot
>
Submit
.
>
.
Cold Reboot
Submit
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Insertion)