Numbering Of The Digital Inputs (Canfagor Bus) - Fagor CNC 8060 Installation Manual

Hide thumbs Also See for CNC 8060:
Table of Contents

Advertisement

2.3.18
2.
CNC 8060
CNC 8065
(R
: 1709)
EF
·94·

Numbering of the digital inputs (CANfagor bus).

NDIMOD
Total number of digital input modules.
Possible values: From 0 to 64.
Default value: 0 (no numbering is defined).
Associated variable: (V.)MPG.NDIMOD
This parameter shows the number of digital input modules connected to the same bus CAN.
After defining this parameter, it is possible to set the numbering of the digital inputs of each
module by assigning a base index to the first of them. If this parameter is not set, the CNC
numbers the digital inputs sequentially according to the order of the modules in the bus.
DIMODADDR
Table of digital input modules.
This parameter shows the list of digital input modules connected to the same bus CAN. When
inserting a new module, the CNC will assign the numbering of the table to the first modules
and the next valid base index after the highest one assigned until then to the last module.
DIMOD n
Base index of the digital input modules.
Possible values: From 0 to 1009.
Default value: The first valid value.
Associated variable: (V.)MPG.DIMODADDR[nb]
Parameter included in the DIMODADDR table.
This parameter sets the base index from which the digital inputs of the module are numbered.
The values of the base index must be comply with the formula "16n + 1" (i.e. 1, 17, 33, etc.).
If an invalid base index is entered, it assumes the nearest previous valid one. The base
indexes may follow any order, they do not have to be sequential.