Configuration of the spindle.

AUTOGEAR
Automatic gear change.
Parameter valid for spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: Yes / No.
Default value: No.
Associated variable: (V.)[ch].MPA.AUTOGEAR.xn
This parameter indicates whether the gear change is automatically generated by activating
(if necessary) the auxiliary functions M41, M42, M43 and M44 when programming the speed.
LOSPDLIM
Lower "rpm OK" percentage.
Parameter valid for spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 0 to 255.
Default value: 50.
Associated variable: (V.)[ch].MPA.LOSPDLIM.xn
See axis machine parameters UPSPDLIM.
UPSPDLIM
Upper "rpm OK" percentage.
Parameter valid for spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 0 to 255.
Default value: 150.
Associated variable: (V.)[ch].MPA.UPSPDLIM.xn
When working with M3 and M4, the REVOK signal is set high when the actual spindle rpm
are between these percentages.
The REVOK signal may be used to manage the Feedhold signal and avoid machining at
lower or higher rpm than the ones programmed.
SPDLTIME
Estimated time for an S function.
Parameter valid for spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 0 to 1000000 ms.
Default value: 0 ms.
Associated variable: (V.)[ch].MPA.SPDLTIME.xn
In EDISIMU mode, there is an option that allows calculating the time required to execute a
part with the machining conditions established in the program.
To fine tune that calculation, one may define this parameter that indicates the estimated time
for processing the S function.
When assigning a value other than "0", the CNC interprets that the "S" value must be passed
on to the PLC using signals SSTROBE + SFUN1.
SPDLSTOP
Functions M2 and M30, an error or a reset stop the spindle.
Parameter valid for spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: Yes / No.
Default value: Yes.
Associated variable: (V.)[ch].MPA.SPDLSTOP.xn
This parameter indicates whether the spindle is stopped or not when executing M02, M30,
when doing a reset or when an error occurs. Otherwise, it will be necessary to program
function M5.
The spindle errors and an emergency always stop the spindle.