Displaying Plc Errors And Messages - Fagor CNC 8060 Installation Manual

Hide thumbs Also See for CNC 8060:
Table of Contents

Advertisement

I n s t a l l a t i o n m a n u a l .
5.5

Displaying PLC errors and messages.

The PLC has 1024 marks for displaying messages and another 1024 marks for displaying
errors at the CNC. When the mark is high (=1) the message or the error is active.
MSG1 - MSG1024
ERR1 - ERR1024
There is a message and error table where each message or error may have associated the
following:
• A number (ID field).
• A text ("Message" field).
• An additional information file ("associated file " field) that may be a "bmp, txt, jpg, gif, htm,
html or avi" type file.
• Whether when activating an error or message the additional help file must be displayed
("Show" field selected) or only the text of the message or of the error.
• For the errors, whether they open the emergency relay of the central unit or not.
For more information on how to edit this table, refer to the operating manual.
PLC messages.
When activating one of the MSG marks, the status bar of the CNC window for PLC messages
shows the message number and its associated text. If the message has a file with additional
information associated with it, an access icon will appear to the left of the message.
The message does not have a file with additional information.
The message has a file with additional information.
When there are more than one message activated, it always shows the one with the highest
priority (the one with the lowest number). The PLC-messages window shows the "+" sign
meaning that there are more messages activated by the PLC. To display the whole list, press
[CTRL] + [M].
If the "Show" field of the message is selected, the CNC screen shows the additional
information file and if there isn't one, a blue window with the text of the message. If the "Show"
field is not selected, to show the additional information file, you must expand the list of
messages, select a message and press [ENTER] or click on the message. To close the
additional data window, press [ESC].
for displaying messages.
for displaying errors.
5.
CNC 8060
CNC 8065
(R
: 1709)
EF
·387·

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cnc 80658060 t power8060 l8060 m fl8060 t fl8060 m power ... Show all

Table of Contents