Remote Module Rcs-S - Fagor CNC 8060 Installation Manual

Hide thumbs Also See for CNC 8060:
Table of Contents

Advertisement

15.4
15.
CNC 8060
CNC 8065
(R
: 1709)
EF
·654·

Remote module RCS-S.

The "RCS-S" counter may be used to get extra feedback (counter) inputs and analog outputs
(remote I/O). These modules are connected to the central unit via Sercos-II bus and they
are just another bus within the bus.
Module
RCS-S-4F4AO
The FeeDat / EnDat support for the RCS-S module is available from the software version v2.01 and
i
hardware version v2.01.
Description.
4 Feedback inputs.
- Incremental TTL, differential TTL and Vpp signal.
- SSI, FeeDat, EnDat 2.1 and EnDat 2.2 protocols.
4 general purpose ±10 V analog outputs (16 bits).
Connector ·E21A·.
Feedback input.
Connector ·E21B·.
Feedback input.
Connector ·E21C·.
Feedback input.
Connector ·E21D·.
Feedback input.
Connector ·I37A·.
2 general purpose analog outputs.
Connector ·I37B·.
2 general purpose analog outputs.
I n s ta ll a t io n ma n u a l.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cnc 80658060 t power8060 l8060 m fl8060 t fl8060 m power ... Show all

Table of Contents