7.3.3
7.
CNC 8060
CNC 8065
(R
: 1709)
EF
·458·

Manager Emergency.

The manager may be set in an Emergency state when a malfunction occurs (the PLC has
executed the wrong action, incomplete tool change, etc.) or if the PLC activates the
emergency.
The PLC marks related to manager emergency are the following: There is one group of marks
for each magazine.
The following table shows the mnemonics for each mark (M) in each channel or magazine.
Magazine ·1·
M
SETTMEM
SETTMEMZ1
M
RESTMEM
RESTMEMZ1
M
TMINEM
TMINEMZ1
The meaning of the marks and registers is as follows.
Marks / Registers.
SETTMEM
RESTMEM
TMINEM
Magazine ·2·
Magazine ·3·
SETTMEMZ2
SETTMEMZ3
RESTMEMZ2
RESTMEMZ3
TMINEMZ2
TMINEMZ3
Meaning,
The PLC sets this mark high (=1) to activate the tool manager
emergency.
The PLC sets this mark high (=1) to cancel the tool manager
emergency.
The CNC sets this mark high (=1) to inform the PLC that an
emergency has occurred at the tool manager. To generate an
emergency at the manager from the PLC:
(1) Activate the emergency.
DFU (error condition) = SET SETTMEM
(2) Make sure that the emergency has occurred before canceling it.
TMINEM AND DFU (removal condition) = SET RESTMEM
The manager sets the SETMEM and RESTMEM signals low
(=0).