Page 2
CNC and at the drives. • Tendency test on analog axes. FAGOR AUTOMATION shall not be held responsible for any personal injuries or physical damage caused or suffered by the CNC resulting from any of the safety elements being disabled.
P a n e l P C . I N D E X About the product - CNC 8065 ..................... 5 Declaration of CE conformity and warranty conditions ..............9 Version history - CNC 8065 ......................11 Safety conditions ........................13 Returning conditions ........................
Page 4
P a n e l P C . 4.4.2 Enclosure design....................... 78 4.4.3 Securing the module....................80 Voltage supply for the module..................81 Hardware functionality. Connectors................82 Connection........................84 4.7.1 Ethernet (Fast Ethernet / Gigabit Ethernet).............. 84 CHAPTER 5 FAGORCONNECT APPLICATION.
Limited to 4 interpolated axes. Option Option Option Option Basic characteristics. 8065 M 8065 M Power 8065 T 8065 T Power Number of handwheels. 1 to 12 Type of servo system. Analog / Digital Sercos / Digital Mechatrolink Communications. RS485 / RS422 / RS232 Ethernet Integrated PLC.
Page 6
P a n e l P C . Remote modules. RIOW RIO5 RIO70 RIOR RCS-S Valid for CNC. 8070 8070 8070 8070 8070 8065 8065 8065 8065 8065 8060 8060 - - - 8060 8060 Communication with the remote modules. CANopen CANopen CANfagor...
Page 7
It limits the number of axes to 4, where the CNC can also into the machine-tool market. With this feature, the PLC interpolate these at the same time. may be programmed either in the usual Fagor language or in IEC 61131 format. SOFT OPEN SYSTEM This feature requires the MP-PLUS (83700201) Open system.
Page 8
This is the new version of algorithms for high speed people without any prior programming knowledge or for machining (HSC). This new HSSA algorithm allows for those that are not familiarized with Fagor CNC's. high speed machining optimization, where higher cutting speeds, smoother contours, a better surface finishing and Working in conversational mode is easier than in ISO greater precision are achieved.
Pa ne l P C. DECLARATION OF CE CONFORMITY AND WARRANTY CONDITIONS DECLARATION OF CONFORMITY The declaration of conformity for the CNC is available in the downloads section of FAGOR’S corporate website. http://www.fagorautomation.com. (Type of file: Declaration of conformity). WARRANTY TERMS The warranty conditions for the CNC are available in the downloads section of FAGOR’s corporate website.
Pa ne l P C. VERSION HISTORY - CNC 8065 Here is a list of the features added to each manual reference. Ref. 1709 First version. Ref. 1801 Corrected errors. CNC 8065 : 1801) ·11·...
Read the following safety measures in order to prevent harming people or damage to this product and those products connected to it. Fagor Automation shall not be held responsible of any physical or material damage originated from not complying with these basic safety rules.
Page 14
Central unit enclosure. To maintain the right ambient conditions in the enclosure of the central unit, it must meet the requirements indicated by Fagor. See the corresponding chapter in the hardware manual. Power switch. This switch must be easy to access and at a distance between 0.7 and 1.7 m (2.3 and 5.6 ft) off the floor.
Page 15
P a n e l P C . Symbols that the product may carry. Ground symbol. This symbol indicates that that point must be under voltage. ESD components. This symbol identifies the cards as ESD components (sensitive to electrostatic discharges). CNC 8065 : 1801) ·15·...
Pa ne l P C. RETURNING CONDITIONS Pack it in its original package along with its original packaging material. If you do not have the original packaging material, pack it as follows: Get a cardboard box whose 3 inside dimensions are at least 15 cm (6 inches) larger than those of the unit itself.
• Do not handle the connectors with the unit supplied with power. Before handling these connectors (I/O, feedback, etc.), make sure that the unit is not powered. • Do not get into the inside of the unit. Only personnel authorized by Fagor Automation may access the interior of this unit.
Page 21
In order to avoid personal injuries and damage to this product or to those connected to it, read carefully the section on safety conditions in the introduction to this manual. Fagor Automation shall not be held responsible of any physical damage or defective unit resulting from not complying with these basic safety regulations.
Page 23
P a n e l P C . MONITOR-21 MULTITOUCH. Monitor to display the VGA video signal from the central unit and also to serve as the touch screen, permitting interaction with the central unit. This monitor may be the only one connected to the central unit (for example, with the central unit MCU) or it may be a second monitor (for example, with the central unit ICU).
- RS-232 (consult Fagor Automation). • Video input. - VGA - DVI-D (consult Fagor Automation). Touch controller. Fagor Automation recommends using the USB driver for the touch screen. Consult Fagor Automation before using the RS232 driver. CNC 8065 : 1801) ·24·...
P a n e l P C . General diagram (MONITOR-21 MULTITOUCH). CNC U65 MONITOR-21W MULTITOUCH CNC U70 MONITOR-21W MULTITOUCH NEUTRO T/S USB OP PANEL HORIZONTAL KEYB VERTICAL KEYB Connection. Description. VGA video signal input. Maximum length; 5 m (16.40 feet) (*). T/S USB Touch screen driver (recommended).
To meet the previous requirements, Fagor recommends the following. • The enclosure must not have any ventilation holes, because they could let dust or other substances Before building an enclosure with glass fiber u another poor heat dissipating material, contact Fagor Automation.
P a n e l P C . 2.4.2 Securing the module. The module must be installed in a proper enclosure that may be located on the machine or on an external support. To insert the unit into the enclosure, it must have a big enough hole to allow to insert it easily, without obstacles and without forcing the unit.
Page 29
P a n e l P C . Fasten the monitor on the rear, using all the fastening hooks (D). 0.7 Nm CNC 8065 : 1801) ·29·...
P a n e l P C . Voltage supply for the module. The monitor has two power supply connections. Fagor Automation recommends using 24 V DC (Phoenix-type connector) to power the monitor. Consult Fagor Automation before using the 12 V DC option.
P a n e l P C . Configuring the video signal from the monitor. The buttons to configure the monitor are on the back. Button Description. Turns the monitor on and off. Power Automatically adjusts the clock, phase, horizontal position and vertical position.
Clear To Send. Ring Indicator. Touch controller. Fagor Automation recommends using the USB driver for the touch screen. Consult Fagor Automation before using the RS232 driver. ·T/S USB· Touch screen driver (recommended). Option recommended by Fagor Automation for the touch controller.
Page 33
"2.5 Voltage supply for the module." on page 30. Power supply. Fagor Automation recommends 24 V DC power for the monitor. Consult Fagor Automation before using the 12 V DC option. Power supply. Never connect both power systems at the same time.
Cable characteristics. 2.8.1 VGA video signal. Fagor Automation supplies the necessary cable for the VGA connection. The cable is valid for static installations such as cable carrying chains. For further information, refer to the Ordering Handbook. Connector pinout. Plug-in part 15-pin female SUB-D HD type connector.
P a n e l P C . OSD (On Screen Display) menu. The selected values are stored in the memory of the monitor after pressing the [Menu/Sel] button at the end of the wait time. The saved values are not lost when the monitor is turned off.
P a n e l P C . 2.9.2 OSD menu. To display the OSD menu, press the MENU key on the back of the monitor. Icon. Description. Video input. Contrast/Brightness. Geometry (for DVI input). Temperature color. Language. OSD configuration. Auto-configuration.
Page 37
P a n e l P C . Video input. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection. OSD sub-menu. Contrast/Brightness. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection.
Page 38
P a n e l P C . Geometry (for DVI input). Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection. OSD sub-menu. Temperature color. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection.
Page 39
P a n e l P C . OSD configuration. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection. OSD sub-menu. Auto-configuration. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection.
Page 40
P a n e l P C . Restore. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection. OSD sub-menu. Exit. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection.
P a n e l P C . 2.9.3 Locks and unlocks the OSD menu. Locks the OSD menu. Press the [Left]+[Right] keys and the following message will appear on screen. Do not release the keys until the screen indicates that the operation has been completed.
Page 43
P a n e l P C . PPC-21W. Panel PC with 21.5 multi-touch monitor to control, operate and monitor the CNC via an ethernet connection. The PPC-21W allows the user to operate the CNC using the touch screen or a USB keyboard (for example, the HORIZONTAL KEYB 2.0 + TOUCHPAD). In both cases, the user can work with the PPC in just the same way as if being in front of the CNC screen.
• 1 audio input. CNC 8065 • 1 audio output. Both the touch controller and VGA connection for the monitor must be connected to the Fagor panel PC. Always use the cables supplied by Fagor for the unit. : 1801)
P a n e l P C . General diagram (PPC-21W). 3.2.1 Networking, without access to the company network. PPC-21W ETHERNET ETHERNET USB 2.0 CNC U65 HORIZONTAL KEYB 2.0 + HBH3 TOUCHPAD HANDHELD TERMINAL CNC U70 OP PANEL Connection. Description. USB 2.0 Connection of a USB keyboard to the PPC-21W.
P a n e l P C . 3.2.2 Connecting to an ethernet network via the PC-panel. COMPANY NETWORK ETHERNET PPC-21W ETHERNET ETHERNET USB 2.0 CNC U65 HORIZONTAL KEYB 2.0 + HBH3 TOUCHPAD HANDHELD TERMINAL CNC U70 OP PANEL Connection. Description.
P a n e l P C . 3.2.3 Connecting to an Ethernet network through a switch. COMPANY NETWORK ETHERNET SWITCH SFNB 5TX ETHERNET ETHERNET ETHERNET CNC U65 PPC-21W HBH3 HANDHELD TERMINAL CNC U70 USB 2.0 OP PANEL HORIZONTAL KEYB 2.0 + TOUCHPAD Connection.
• To improve heat dissipation, install an internal fan inside the enclosure for air circulation. Before building an enclosure with glass fiber u another poor heat dissipating material, contact Fagor Automation. Dimensions of the cut off part and the enclosure.
Page 50
P a n e l P C . Recommended minimum clearances between the PPC-21W and the enclosure walls. inch D (*) > 50 > 1.97 (*) Minimum recommended distance. Dissipated power inside the enclosure. To calculate the total surface area the enclosure must have to dissipate the heat inside, we must consider the dissipated power for all the elements that generate heat inside the enclosure.
P a n e l P C . 3.4.3 Securing the module. The module must be installed in a proper enclosure that may be located on the machine or on an external support. To insert the unit into the enclosure, it must have a big enough hole to allow to insert it easily, without obstacles and without forcing the unit.
Page 52
P a n e l P C . Rest the monitor inside the enclosure on the lower stop screws and push the top part until the pressure hooks support the monitor. Fasten the PPC-21W at the rear, using all the attachment fixtures (D). 0.7 Nm CNC 8065 : 1801)
Monitor power: 12 V DC (consult Fagor Automation). Panel PC power: 24 V DC. The monitor has two different voltage power supply ports (24 and 12 V DC). Fagor Automation recommends using 24 V DC (Phoenix-type connector) to power the monitor.
P a n e l P C . Hardware functionalities. 3.6.1 Rear keyboard. The rear keyboard allows the monitor video signal ("3.7 Configuring the video signal from the monitor.") to be configured and to navigate Power through the OSD menu ("3.9 OSD (On Screen Display) menu.").
DC jack connector for the external current adapter. See "3.5 Voltage supply for the module." on page 53. Fagor Automation recommends 24 V DC power for the monitor. Consult Fagor Automation before using CNC 8065 the 12 V DC option.
2 USB 2.0 Type-A ports, Plug & Play compatible. The USB interface is compliant with USB EHCI specification, rev. 2.0. Connect the monitor’s T/S USB (touch controller) output to one of these inputs. Always use the cable supplied by Fagor for the unit. ·USB 3.0· 2 USB 3.0 Type-A ports.
P a n e l P C . ·LAN A / LAN B· Ethernet. The PPC-21W has 4 RJ45 LAN ports, two at the lower end (LAN A / LAN B) and two at the upper end (LAN C / LAN D). All ports comply with the IEEE 802.3u 10 / 100Base-T CSMA/CD standard and are compliant with the IEEE 802.3ab 1000Base-T specification.
Page 58
P a n e l P C . Power button. Button to turn the panel PC on and off. ·RST· Reset button. Button to activate the hardware reset function. ·Tx Rx· Transmission and reception LEDs. Data transmission and reception LEDs on the COM ports. ·BTR·...
P a n e l P C . 3.6.4 Panel PC (top end connectors). Bottom view. COM1 / COM2 RS-232 serial line. LAN C / LAN D Ethernet. HD Audio High definition audio output. HD Expansion. n/a. ·COM1 / COM2· RS-232 serial line. 2 COM ports for RS-232 serial lines, 50 ~ 115.2 kbps.
P a n e l P C . Configuring the video signal from the monitor. The buttons to configure the monitor video signal are on the back. This keyboard is also used for the OSD menu. Button. Description. Turns the monitor on and off. Power Automatically adjusts the clock, phase, horizontal position and vertical position.
VGA Video input on the monitor. Cable characteristics. Fagor Automation supplies the necessary cable for the VGA connection between the panel PC and the monitor. Always use the cable supplied by Fagor for the unit. CNC 8065 : 1801) ·61·...
The monitor’s touch controller output. Generic USB 2.0 input on the panel PC. Cable characteristics. Fagor Automation supplies the necessary cable for the touch controller. Always use the cable supplied by Fagor for the unit. CNC 8065 : 1801)
P a n e l P C . 3.8.3 Ethernet (Fast Ethernet / Gigabit Ethernet). The PPC-21W has 4 RJ45 LAN ports, two at the lower end (LAN A / LAN B) and two at the upper end (LAN C / LAN D). All ports comply with the IEEE 802.3u 10 / 100Base-T CSMA/CD standard and are compliant with the IEEE 802.3ab 1000Base-T specification.
Page 64
P a n e l P C . Element connection. In order to ensure proper performance, the connection cable must be inserted all the way into the connectors so they're latched. This ensures that the cable is properly latched and does not come off due to vibration.
P a n e l P C . OSD (On Screen Display) menu. The selected values are stored in the memory of the monitor after pressing the [Menu/Sel] button at the end of the wait time. The saved values are not lost when the monitor is turned off.
Page 66
P a n e l P C . 3.9.2 OSD menu. To display the OSD menu, press the MENU key on the back of the monitor. Icon. Description. Video input. Contrast/Brightness. Geometry (for DVI input). Temperature color. Language. OSD configuration. Auto-configuration.
Page 67
P a n e l P C . Video input. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection. OSD sub-menu. Contrast/Brightness. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection.
Page 68
P a n e l P C . Geometry (for DVI input). Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection. OSD sub-menu. Temperature color. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection.
Page 69
P a n e l P C . OSD configuration. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection. OSD sub-menu. Auto-configuration. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection.
Page 70
P a n e l P C . Restore. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection. OSD sub-menu. Exit. Select this menu icon using the [Left] and [Right] keys and press the [Menu/Sel] key to confirm the selection.
P a n e l P C . 3.9.3 Locks and unlocks the OSD menu. Locks the OSD menu. Press the [Left]+[Right] keys and the following message will appear on screen. Do not release the keys until the screen indicates that the operation has been completed.
P a n e l P C . PPC-19. Panel PC with 19 multi-touch monitor to control, operate and monitor the CNC via an ethernet connection. The PPC-19 allows the user to operate the CNC using the touch screen or a USB keyboard (for example, the HORIZONTAL KEYB 2.0 + TRACKHPAD).
P a n e l P C . Specifications. Type. Description. General. • 19" monitor (1280 × 1024 px), capacitive multi-touch (10 points). • SO: Windows 7. • Dimensions (width x height x depth) - 480 × 400 × 60.40 mm. - 18.90"...
P a n e l P C . General diagram (PPC-19 ). 4.2.1 Point-to-point connection with the CNC. PPC-19 ETHERNET ETHERNET USB 2.0 CNC U65 HORIZONTAL KEYB 2.0 + HBH3 TOUCHPAD HANDHELD TERMINAL CNC U70 OP PANEL Connection. Description. USB 2.0 Connection of a USB keyboard to the PPC-19.
P a n e l P C . 4.2.2 Connecting to an Ethernet network through a switch. COMPANY NETWORK ETHERNET SWITCH SFNB 5TX ETHERNET ETHERNET ETHERNET CNC U65 PPC-19 HBH3 HANDHELD TERMINAL CNC U70 USB 2.0 OP PANEL HORIZONTAL KEYB 2.0 + TOUCHPAD Connection.
• To improve heat dissipation, install an internal fan inside the enclosure for air circulation. Before building an enclosure with glass fiber u another poor heat dissipating material, contact Fagor Automation. Dimensions of the cut off part and the enclosure.
Page 79
P a n e l P C . Minimum distances recommended to the enclosure walls. inch D (*) 1.97 (*) Minimum recommended distance. Dissipated power inside the enclosure. To calculate the total surface area the enclosure must have to dissipate the heat inside, we must consider the dissipated power for all the elements that generate heat inside the enclosure.
P a n e l P C . 4.4.3 Securing the module. The module must be installed in a proper enclosure that may be located on the machine or on an external support. To insert the unit into the enclosure, it must have a big enough hole to allow to insert it easily, without obstacles and without forcing the unit.
P a n e l P C . Voltage supply for the module. Power supply. Monitor power: 12 ~ 24 V DC. Power the monitor with a 12 ~ 24 V DC power supply. Signal. Function. - - -. 0 V reference signal. Power supply.
P a n e l P C . Hardware functionality. Connectors. Connector. Description. USB 2.0 2 USB 2.0 Type-A ports. RS-232/422/485 2 RS-232/422/485 serial lines. DVI-D Video signal output. USB 2.0 1 USB 2.0 Type-A ports. USB 3.0 1 USB 3.0 Type-A ports. 2 RJ45 LAN ports (10/100/1000 Mbps).
Power status LED (green LED). The LED turns on when the panel PC is powered, otherwise the LED is turned off. ·24 V DC IN· Supply input (recommended). Option recommended by Fagor Automation to power the monitor. Plug-in part 3-pole Phoenix-type connector (5.08 mm pitch). Rated current; 16 A.
P a n e l P C . Connection. 4.7.1 Ethernet (Fast Ethernet / Gigabit Ethernet). RJ-45 The PPC-19 can be configured as an additional node on a local network or it may be connected point-to-point to the CNC. Connector. All ports have two LEDs to indicate whether the PPC-19 is connected to the network (green LED) and if data are being transmitted (yellow LED).
Press the "Install" button to start the installation and follow the instructions that appear on screen. • To install the application on a Fagor Panel PC, it must be in administrator mode (with the disk unprotected). See "5.4 Work modes."...
P a n e l P C . The FagorConnect application. The main objective of the application is to connect the Panel PC to the CNC through the remote Desktop as soon as the application starts and in a way that is transparent to the user. After establishing the connection, the Panel PC will display the same information as the CNC, so that the user can work with the Panel PC just as if it were a screen connected to the CNC.
P a n e l P C . Configure the application. The "Configuration" button at the top shows the window to configure the connection to the CNC. When the application starts, it displays the current configuration saved in the FagorConnect.ini file. The configuration is saved in this file when the "Save Configuration" or "Connect”...
• $Recycler.bin Recycling bin. • C:\Public Network shared folder. • C:\Program Files (x86)\Fagor Automation\FagorConnect\FagorConnect.ini Configuration file for the FagorConnect application. • C:\Program Files (x86)\Fagor Automation\FagorConnect\FagorConnect.rdp Configuration file for the remote desktop connection. In administrator mode, the buttons "Add new file/folder" and "Remove file/folder" allow you to add and remove files/folders in the protected files/folders list.
P a n e l P C . Diagnosis. The "Diagnosis" button at the top shows information about the Panel PC itself. The "Save to file" button allows you to save the information in a file. Accessing Panel PC resources from the CNC. The Panel PC is configured to export its resources so that the CNC can see your hard drive and any possible pen drives that are connected.