I n s t a l l a t i o n m a n u a l .
2.6.19
Analog command setting.
SERVOOFF
Offset compensation.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for an analog drive.
Possible values: Within ±32767.
Default value: 0.
Associated variable: (V.)[ch].MPA.SERVOOFF[set].xn
Velocity command applied as offset to the drive. The velocity command is given in D/A
converter units that could be any integer within ±32767; a value of ±32767 corresponds to
an analog velocity command of ±10V.
SERVOOFF
-32767
···
-3277
···
1
···
3277
···
32767
MINANOUT
Minimum velocity command.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for an analog drive.
Possible values: From 0 to 32767.
Default value: 0.
Associated variable: (V.)[ch].MPA.MINANOUT[set].xn
The velocity command is given in D/A converter units that could be any integer between 0
and 32767; a value of ±32767 corresponds to an analog velocity command of 10V.
MINANOUT
1
···
3277
···
32767
Ve l o c i t y
command.
-10 V.
···
-1 V.
···
0,3 mV.
···
1 V.
···
10 V.
Ve l o c i t y
command.
0,3 mV.
···
1 V.
···
10 V.