Number of the analog output and of the feedback input associated with
the axis.
ANAOUTTYPE
Type of analog output associated with the axis.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for an analog drive.
Possible values: Remote CAN / Drive / Sercos Counter / Local.
Default value: Remote CAN.
Associated variable: (V.)[ch].MPA.ANAOUTTYPE[set].xn
This parameter is only valid for analog axes and indicates where the analog output is located;
in the remote CAN modules, in a Sercos drive or in an RCS-S module (Sercos counter) or
local. Local analog output only on the 8060.
ANAOUTID
Number of the analog output associated with the axis.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for an analog drive.
Possible values: From 1 to 16 for remote modules / Sercos drives, from 101 to 132 or from 201 to 232
/ Sercos counter, rom 1 to 32.
Default value: 0.
Associated variable: (V.)[ch].MPA.ANAOUTID[set].xn
The velocity command for an analog axis may be taken from an analog output of the remote
CAN modules or of a Sercos drive. or of an RCS-S module (Sercos counter). In either case,
this parameter indicates the analog output used for the command.
When two axes will not be in the configuration at the same time, the CNC allows using the
same analog output for both axes.
Managing the analog command from CAN remote modules.
In this case, this parameter indicates the number of the analog output used for the command.
The analog output modules are numbered following the logic order of the remote groups
(rotary switch of the power supply). If there are several analog-output modules in each group,
the order is from top to bottom and from left to right. The analog outputs of the first module
will be 1 through 4, those of the second module 5 through 8 and so on.
Managing the analog command from Sercos drives.
In this case, this parameter indicates the number of the analog output and the drive to be
used. The parameter is set with a three-digit number; the first digit indicates the number of
the analog output to be used (1 or 2) and the other two digits indicate the logic address of
the drive (1 through 32). The "address" rotary selector switch sets the logic address.
For example, if the parameter is with a value of ·107·, it indicates that the CNC uses analog
input ·1· of the drive whose logic address is ·7· In this case, to consult the voltage at this
output, the variable must be written as V.G.ANAO[107].
i
The parameters OP1 and OP2 of the drive must be set to 0.
Managing the analog command from the RCS-S module.
In this case, this parameter indicates the number of the analog output used for the command.
The RCS-S modules are numbered according to their logic order (parameter
SERCOUNTID). The analog outputs of the first module will be 1 through 4, those of the
second module 5 through 8 and so on.
I n s ta ll a t io n ma n u a l.