The next field to the right of the At
Marker field will pop
when selected and show you all thelabels assigned to the timing
up
analyzer as shown below.
.
pijzEmq-
liming
Wavelams
I
Figure 1940. Label Option Pop-up
Time/Div (time
per division)
Field
Note d
The time per division field allows YOU to change the width of the time
window of the Timing Waveformsmenu.
When the pop-up is open you can change the time per division by
rotating the KNOB or entering a numeric value from the keypad. When
you rotate the KNOB, the time per division increments or decrements
in
l-2-5
sequence from
10
ns/div to 50 ms/div.
Sample period is fixed at
10
ns in the Transitional acquisition mode.
When you enter a value from the keypad, the time per division does not
have to be a
l-2-5
sequence.
Note I&
In Glitch mode, changing the Time/Div setting changes the sample
period for the next run. To view the sample period after the next run,
turn the markers off if they are on and press RUN.