4. In State Format Specification assign the lower eight bits of the pod under test
to a label as shown in figure 3-33. Make sure the appropriate
eight bits in the
bit assignment field are turned on.
VI/-
Tlmlng
Foram t Speclf
lea lion
Pod
1
I
l-l-L
I
Activity
> ,,,,,,,,ts*tsttt
Label
Pol
15 .,.,
87
.,.,
0
or +
, I . , . , . I LI***IL*
(Specify
Symbols
1
Figure 3-33. Glitch Test Timing
Format Specification
5. Set Timing Trace Specification
as in figure 3-34. Follow steps a through d if
you are unfamiliar with menus.
I
lnACHINE]I-
flmlng
Trace
Speclflcatlon
Trace
model-1
Armed
by 1-1
Acquisition
mode 1
G1 itch
]
Lob
Ba
Fln
P
present
for
The
n find
Edge I..
Or
Gil tch -1
]
30ns
1
Figure 3-34. Glitch Test Timing
Trace Specification
a. Move the cursor to the Acquisition
mode field and select the Glitch
mode.
b. Move the cursor to the Find Pattern field and press SELECT.
Assign
all Don't Cares (all Xs) and press SELECT.
c. Set the Present for field to >30 ns.
d. Set Then find Glitch "on" for all channels (* = on; . = off).