s/Div Field
The s/Div field sets the sweep speed or time scale on the horizontal axis
of the display and is measured in seconds/division. The display is
divided into
10
horizontal divisions. The divisions are marked by small
tick marks at the top and bottom of the waveform display.
When the s/Div field is selected, a pop-up will appear and the sweep
speed of the channel selected in the Input field can be changed by
turning the knob. See the upper pop-up in figure 23-15.
Keypad entry pop-up y
CH 1
7
1
Mumeric
Entry
0 E
(to>
g
US
\
0,
nc
Figure 23-15. s/Div Entry Pop-ups
As the sweep speed is changed, the signal expands and compresses in
both directions from the center of the display. As you turn the knob,
the sweep speed changes in a l-2-5 sequence from 5 ns/Div to 5 s/Div.
Sweep speed can also be entered from the Numeric Entry pop-up. The
pop-up will appear when the first numeric key is touched. See the
lower pop-up in figure 23-15.
Any value from 5 ns/Div to 5 s/Div can be enter from the keypad.
Sweep speed can be set to three-digit resolution. For example, if you
entered a value of 15.45 ns, the value would be rounded up to 15.5 ns.