HP 1652B Getting Started Manual page 496

Logic
Hide thumbs Also See for 1652B:
Table of Contents

Advertisement

HP 16528/16538
Front-Panel Reference
Invalid file name. Check the file name.
A file name must
alpha character and cannot contain spaces or
slashes (/).
with
an
Inverse assembler not loaded-bad object code.
Indicates a bad inverse
assembler file on
the
disc. A new disc or file is required.
Maximum of 32 channels per label. Indicates an attempt to assign
more than 32 channels to a label. Reassign channels so that
no more
than 32 are assigned to a label.
No room on destination-file not copied.
Indicates the destination disc
doesn't have enough room for
the
file you are attempting to copy. Try
packing the disc and repeating the copy operation. If this
is
unsuccessful, you will need to use a different disc.
(x) Occurrences Remaining in Sequence.
Indicates the logic
analyzer is
waiting for (x) number of occurrences in a sequence level of the trigger
specification before it can go on to the next sequence level.
PRINT has been stopped. This message appears when the print
operation has been stopped.
(x) Sets Remaining in Trace. Indicates
the
amount of time remaining
until acquisition is complete in Glitch mode.
Search failed - 0 pattern not found. Indicates
the
0 pattern does not
exist in the acquired data. Check for a correct 0 marker pattern
specification.
Search failed - X pattern not found. Indicates the X pattern does not
exist in the acquired data. Check for a correct X marker pattern
specification.
Slow Clock or Waiting for Arm. Indicates the state analyzer is waiting
for a clock or arm from the other machine. Recheck the state clock or
arming specification.
Error Messages
c-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

1653b

Table of Contents