4.6.4 Operator Display during Testing without Motor
The status display changes as shown below to show that the test without motor is in progress.
(1) Display on Panel Operator
∗
The test without motor operation is indicated with tSt.
Display
run ⇔ tSt
bb ⇔ tSt
Pot ⇒ not ⇒ tSt
Pot ⇔ tSt
not ⇔ tSt
Hbb ⇔ tSt
Note: The test without motor status is not displayed during alarm occurs (A.
(2) Display on Digital Operator
∗ mark is displayed before status display to indicate the test without motor operation is in progress.
∗ B B
U n 0 0 0 =
0
0 0 0 0 0
U n 0 0 2 =
0
0 0 0 0 0
U n 0 0 8 =
0
0 0 0 0 0 0 0 0 0 0
U n 0 0 D =
0
0 0 0 0 0 0 0 0 0 0
(Example: Status of power to the motor is OFF)
Display
*RUN
*BB
*P DET
*PT NT
*P-OT
*N-OT
*HBB
Note: The test without motor status is not displayed during alarm occurs (A.
Displayed alternately
Power is supplied to the motor.
Power to the motor is OFF.
Forward or reverse rotation is prohibited.
Driving in the forward direction is prohibited.
Driving in the reverse direction is prohibited.
In hard-wire base block (safety) state.
− P R M / M O N −
Power is supplied to the motor.
Power to the motor is OFF.
The polarity is being detected.
Forward or reverse rotation is prohibited.
Driving in the forward direction is prohibited.
Driving in the reverse direction is prohibited.
In hard-wire base block (safety) state.
Status
).
Status
).
4.6 Test Without Motor Function
4
4-15