YASKAWA SGMJV User Manual page 212

Ac ?-v series
Hide thumbs Also See for SGMJV:
Table of Contents

Advertisement

6 Adjustments
6.3.1 Advanced Autotuning
• Anti-resonance control
• Vibration suppression (Mode = 2 or 3)
Refer to 6.3.3 Related Parameters for parameters used for adjustments.
• Because advanced autotuning adjusts the SERVOPACK during automatic operation, vibration or over-
shooting may occur. To ensure safety, perform advanced autotuning in a state where the SERVOPACK
can come to an emergency stop at any time.
(1) Before Performing Advanced Autotuning
Check the following settings before performing advanced autotuning.
a) A message (NO-OP) indicating that no operations are possible will be displayed, if all of the following
conditions are not met.
• The main circuit power supply must be ON.
• The servo ON (/S_ON) signal must be OFF.
• The forward run prohibited (P-OT) and the reverse run prohibited (N-OT) signals must not be in an over-
travel state.
• The control must not be set to torque control.
• Automatic gain switching must be disabled.
• Gain setting 2 must not be selected.
• Test without motor function must not be enabled. (Pn00C.0 = 0)
• All alarms and warning must be cleared.
• The hardwire baseblock (HWBB) must be off.
b) Observe the following condition to ensure operation.
• The write prohibited setting (Fn010) must not be set.
Note: If advanced autotuning is started while the SERVOPACK is in speed control, the mode will change to position con-
trol automatically to perform advanced autotuning. The mode will return to speed control after completing the
adjustment. To perform advanced autotuning in speed control, set the mode to 1. (Mode = 1)
(2) When Advanced Autotuning Cannot be Performed
Advanced autotuning cannot be performed normally under the following conditions. If any of the following
conditions exists, perform advanced autotuning by reference or one-parameter tuning.
Refer to 6.4 Advanced Autotuning by Reference (Fn202) and 6.5 One-parameter Tuning (Fn203) for details.
• The machine system can work only in a single direction.
• The operating range is within 0.5 rotations. (Also for SGMCS direct drive motors, the operating range is
within 0.05 rotations.)
(3) When Advanced Autotuning Cannot be Adjusted
Advanced autotuning may not be performed normally under the following conditions. If the result of autotun-
ing is not satisfactory, perform advanced autotuning by reference or one-parameter tuning.
Refer to 6.4 Advanced Autotuning by Reference (Fn202) and 6.5 One-parameter Tuning (Fn203) for details.
• The operating range is not applicable.
• The moment of inertia changes within the set operating range.
• The machine has high friction.
• The rigidity of the load is low and vibration occurs when positioning is performed.
• The position integration function is used.
• P control operation (proportional control) is performed.
Note:If a setting is made for calculating the moment of inertia, an error will result when P control operation is selected
6-18
using /P-CON signal while the moment of inertia is being calculated.
CAUTION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgdvSgmavSgmpsSgmgvSgmcs

Table of Contents