Parameter Setting Mode For Function Selection Type - YASKAWA SGMJV User Manual

Ac ?-v series
Hide thumbs Also See for SGMJV:
Table of Contents

Advertisement

2 Panel Operator

2.6.2 Parameter Setting Mode for Function Selection Type

2.6.2 Parameter Setting Mode for Function Selection Type

The parameter setting mode of the function selection type is used to select and set the function allocated to
each digit displayed on the panel operator.
(1) Changing Function Selection Parameter Settings
The example below shows how to change the setting of control method selection (Pn000.1) of the function
selection basic switch Pn000 from speed control to position control.
Step
1
2
3
4
5
6
7
2-10
Display after
Operation
MODE/SET
MODE/SET
MODE/SET
MODE/SET
Display blinks
MODE/SET
MODE/SET
To enable the change in the setting, turn the power OFF and ON again.
Keys
Press the MODE/SET Key to select the parameter setting
mode. If Pn000 is not displayed, press the UP or the
DOWN Key to select Pn000.
DATA/
Press the DATA/SHIFT Key for approximately one sec-
ond. The current data of Pn000 is displayed.
DATA/
Press the DATA/SHIFT Key once to select the second digit
of current data.
DATA/
Press the UP Key once to change "n.0010."
(Set the control method to position control.)
DATA/
Press the MODE/SET Key. The value blinks and is saved.
The control method is changed to position control.
DATA/
Press the DATA/SHIFT Key for approximately one sec-
ond. "Pn.000" is displayed again.
DATA/
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgdvSgmavSgmpsSgmgvSgmcs

Table of Contents