11 Appendix
11.2.2 Parameters
Parameter
No.
Application Function Select Switch 8
4th
digit
n.
Pn008
Application Function Select Switch 9
4th
digit
n.
Pn009
11-12
Name
0000 to 7121
3rd
2nd
1st
digit
digit
digit
Lowered Battery Voltage Alarm/Warning Selection
0
Outputs alarm (A.830) for lowered battery voltage.
1
Outputs warning (A.930) for lowered battery voltage.
Function Selection for Insufficient Voltage
0
Disables detection of insufficient voltage.
1
Detects warning and limits torque by host controller.
2
Detects warning and limits torque by Pn424 and Pn425.
Warning Detection Selection
0
Detects warning.
Does not detect warning.
1
Reserved (Do not change.)
0000 to 0111
3rd
2nd
1st
digit
digit
digit
Reserved (Do not change.)
Current Control Method Selection
Current control method 1
0
Current control method 2
1
Speed Detection Method Selection
0
Speed detection 1
1
Speed detection 2
Reserved (Do not change.)
Setting
Factory
Units
Range
Setting
−
0000
−
0010
When
Classification
Enabled
After restart
Setup
(Refer to 5.9.4)
(Refer to 5.9.4.)
(Refer to 5.2.7)
(Refer to 5.2.7.)
(Refer to 10.2.1)
(Refer to 10.2.1.)
After restart
Tuning
(Refer to 6.8.3)
(Refer to 6.8.5)
Reference
Section
−
−