Operating Procedure - YASKAWA SGMJV User Manual

Ac ?-v series
Hide thumbs Also See for SGMJV:
Table of Contents

Advertisement

4 Trial Operation

4.6.3 Operating Procedure

4.6.3 Operating Procedure

Follow the steps below to execute the test without motor using panel operator.
Step
1
2
3
4
5
6
7
8
9
10
11
12
4-14
Display after Operation
(Display blinks)
(Display blinks)
To enable the change in the setting, turn the power OFF and ON again.
Keys
Press the MODE/SET Key to select the utility function
mode.
MODE/SET
DATA/
Press the UP or DOWN Key to select the Pn00C.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one sec-
ond. The current data of Pn00C is displayed.
MODE/SET
DATA/
To enable the test without motor, press the UP Key to
change the setting from n.
n.
n.
MODE/SET
DATA/
n.
Press the MODE/SET Key. The display began to blink
and the test without motor is enabled.
MODE/SET
DATA/
Press the DATA/SHIFT Key once to select the first digit
of the data.
MODE/SET
DATA/
Press the UP or DOWN Key to select the encoder resolu-
tion.
n.
0
MODE/SET
DATA/
n.
1
Press the MODE/SET Key. The display began to blink
and the encoder resolution is set to 20 bit.
MODE/SET
DATA/
Press the DATA/SHIFT Key once to select the second
digit of the data.
MODE/SET
DATA/
Press the UP or DOWN Key to select the encoder type.
n.
0
n.
1
MODE/SET
DATA/
Press the MODE/SET Key. The display began to blink
and the incremental encoder is selected.
MODE/SET
DATA/
Description
0 (factory setting) to
1.
0: Test without motor disabled.
1: Test without motor enabled.
: 13 bit (factory setting)
: 20 bit
: incremental encoder (factory setting)
: absolute encoder

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgdvSgmavSgmpsSgmgvSgmcs

Table of Contents