YASKAWA SGMJV User Manual page 251

Ac ?-v series
Hide thumbs Also See for SGMJV:
Table of Contents

Advertisement

(3) Automatic Gain Switching
Automatic gain switching is performed under the following settings and conditions.
Parameter Setting
Pn139=n.
2
(Automatic Switching)
Select one of the following settings for switching condition A.
Parameter
n.
0
n.
1
n.
2
Pn139
n.
3
n.
4
n.
5
Automatic switching pattern 1 (Pn139.0 = 2)
Gain
Settings 1
Pn100
Pn101
Pn102
Pn121
Pn401
Switching Setting
Condition A estab-
Gain Setting 1 to
lished.
Gain Setting 2
Condition A not estab-
Gain Setting 2 to
lished.
Gain Setting 1
Switching Condition A
Other than Position
Position Control
Positioning completed
Fixed in gain setting 1
signal (/COIN) ON
Positioning completed
Fixed in gain setting 2
signal (/COIN) OFF
NEAR signal
Fixed in gain setting 1
(/NEAR) ON
NEAR signal
Fixed in gain setting 2
(/NEAR) OFF
No output for position
reference filter and refer-
Fixed in gain setting 1
ence pulse input OFF
Position reference pulse
Fixed in gain setting 2
input ON
Switching Waiting Time 1 Pn135
Condition A
established
Switching Waiting Time 2 Pn136
Switching Time 2 Pn132
6.8 Additional Adjustment Function
Switching Wait
Setting
Time
Gain Switching
Waiting Time 1
Pn135
Gain Switching
Waiting Time 2
Pn136
When
Enabled
Control
Immediately
Switching Time 1 Pn131
Condition
A not established
Switching Time
Gain Switching
Time 1
Pn131
Gain Switching
Time 2
Pn132
Classification
Tuning
Gain
Settings 2
Pn104
Pn105
Pn106
Pn122
Pn412
6-57
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgdvSgmavSgmpsSgmgvSgmcs

Table of Contents