6 Adjustments
6.8.1 Switching Gain Settings
(5) Parameters for Automatic Gain Switching
Pn131
Pn132
Pn135
Pn136
(6) Related Monitor
Monitor No. (Un)
Un014
Note: When using the tuning-less function, gain setting 1 is enabled.
Parameter
Pn006
Pn007
6-60
Gain Switching Time 1
Setting Range
0 to 65535
Gain Switching Time 2
Setting Range
0 to 65535
Gain Switching Waiting Time 1
Setting Range
0 to 65535
Gain Switching Waiting Time 2
Setting Range
0 to 65535
Name
Effective gain monitor
Analog
Monitor
Effective gain moni-
n.
0B
tor
Setting Unit
Factory Setting
1 ms
Setting Unit
Factory Setting
1 ms
Setting Unit
Factory Setting
1 ms
Setting Unit
Factory Setting
1 ms
Value
1
For gain setting 1
2
For gain setting 2
Name
Output Value
1 V
2 V
Position
Speed
When Enabled
0
Immediately
Position
Speed
When Enabled
0
Immediately
Position
Speed
When Enabled
0
Immediately
Position
Speed
When Enabled
0
Immediately
Remarks
Remarks
Gain setting 1 is enabled.
Gain setting 2 is enabled.
Classification
Tuning
Classification
Tuning
Classification
Tuning
Classification
Tuning