4.6.4 Operator Displays during Testing without Motor
The status display changes as shown below to show that the test without a motor is being executed.
(1) Display on Panel Operator
∗
The test without a motor operation in progress is indicated with tSt.
Display
run ⇔ tSt
bb ⇔ tSt
Pot ⇒ not ⇒ tSt
Pot ⇔ tSt
not ⇔ tSt
Hbb ⇔ tSt
Note: The test without a motor status is not displayed during alarm occurs (A.
(2) Display on Digital Operator
An asterisk (∗) is displayed before status display to indicate the test without a motor operation is in progress.
∗ B B
U n 0 0 0 =
0
0 0 0 0 0
U n 0 0 2 =
0
0 0 0 0 0
U n 0 0 8 =
0
0 0 0 0 0 0 0 0 0 0
U n 0 0 D =
0
0 0 0 0 0 0 0 0 0 0
(Example: Status of power to the servomotor is OFF)
Display
*RUN
*BB
*PT NT
*P-OT
*N-OT
*HBB
Note: The test without a motor status is not displayed during alarm occurs (A.
Displayed alternately
Power is supplied to the servomotor.
Power to the servomotor is OFF.
Forward or reverse run is prohibited.
Forward run is prohibited.
Reverse run is prohibited.
In hard-wire base block (safety) state.
− P R M / M O N −
Power is supplied to the servomotor.
Power to the servomotor is OFF.
Forward or reverse run is prohibited.
Forward run is prohibited.
Reverse run is prohibited.
In hard-wire base block (safety) state.
Analog
Status
).
Status
).
4.6 Test Without Motor Function
4