YASKAWA SGMJV User Manual page 300

Ac ?-v series
Hide thumbs Also See for SGMJV:
Table of Contents

Advertisement

7 Utility Functions (Fn
(1) Operating Procedure
Follow the steps below.
Step
1
2
3
7-32
)
When using mainly for servo gain adjustment, etc.
With the servo ON, execute
Online Vibration Monitor
(Fn207)
• Starts EasyFFT when the servo ON (/S_ON) signal is OFF.
• Do not input the reference from outside because EasyFFT outputs the special
reference from the SERVOPACK.
Display after
Operation
MODE/SET
MODE/SET
Setting reference
MODE/SET
amplitude
Start
Vibration with
No
high-frequency noise
during operation
Yes
Turn OFF the servo, and
execute EasyFFT (Fn206)
Adjsut servo gain
No
Vibration
Yes
End
Keys
Press the MODE/SET Key to select the utility function
mode.
DATA/
Press the UP or DOWN Key to select Fn206.
DATA/
Press the DATA/SHIFT for approximately one second. The
display shown on the left appears. The panel operator is in
the reference amplitude setting mode.
Note: When "no-oP" blinks for approximately one second,
the write prohibited setting is set in Fn010. Change
DATA/
the setting in Fn010, and press the key again after
enabling writing. (Refer to 7.12.)
Operation