Parameter
Name
No.
Input Signal Selection 4
4th
3rd
2nd
digit
digit
digit
n.
Pn50D
Output Signal Selection 1
4th
3rd
2nd
digit
digit
digit
n.
Pn50E
Setting
Range
0000 to FFFF
1st
digit
/ZCLAMP Signal Mapping (Zero clamp when ON (L-level))
0
ON when CN1-40 input signal is ON (L-level).
1
ON when CN1-41 input signal is ON (L-level).
2
ON when CN1-42 input signal is ON (L-level).
3
ON when CN1-43 input signal is ON (L-level).
4
ON when CN1-44 input signal is ON (L-level).
5
ON when CN1-45 input signal is ON (L-level).
6
ON when CN1-46 input signal is ON (L-level).
7
Sets signal ON.
8
Sets signal OFF.
9
ON when CN1-40 input signal is OFF (H-level).
A
ON when CN1-41 input signal is OFF (H-level).
B
ON when CN1-42 input signal is OFF (H-level).
C
ON when CN1-43 input signal is OFF (H-level).
D
ON when CN1-44 input signal is OFF (H-level).
E
ON when CN1-45 input signal is OFF (H-level).
F
ON when CN1-46 input signal is OFF (H-level).
/INHIBIT Signal Mapping (Reference pulse inhibit when ON (L-level))
0 to F Same as /ZCLAMP
/G-SEL1 Signal Mapping (Gain change when ON (L-level))
0 to F Same as /ZCLAMP
Reserved (Do not change.)
0000 to 3333
1st
digit
Positioning Completion Signal Mapping (/COIN)
0
Disabled (the above signal is not used.)
1
Outputs the signal from CN1-25, 26 output terminal.
2
Outputs the signal from CN1-27, 28 output terminal.
3
Outputs the signal from CN1-29, 30 output terminal.
Speed Coincidence Detection Signal Mapping (/V-CMP)
0 to 3 Same as /COIN
Servomotor Rotation Detection Signal Mapping (/TGON)
0 to 3 Same as /COIN
Servo Ready Signal Mapping (/S-RDY)
0 to 3 Same as /COIN
Factory
When
Units
Setting
Enabled
−
8888
After restart
−
3211
After restart
11.2 List of Parameters
Reference
Classification
Section
Setup
−
(Refer to 5.3.5)
(Refer to 5.3.5.)
(Refer to 5.4.7)
(Refer to 5.4.7.)
(Refer to 6.9.6)
(Refer to 6.8.6.)
−
Setup
(Refer to 5.4.5)
(Refer to 5.4.5.)
(Refer to 5.3.8)
(Refer to 5.3.8.)
(Refer to 5.10.3)
(Refer to 5.10.3.)
(Refer to 5.10.4)
(Refer to 5.10.4.)
11-25