11 Appendix
11.2.2 Parameters
Parameter
No.
Input Signal Selection 3
4th
digit
n.
Pn50C
11-24
Name
0000 to FFFF
3rd
2nd
1st
digit
digit
digit
/SPD-D Signal Mapping (See the internal set speed control function.)
0
Active on the falling edge of CN1-40 input signal.
1
Active on the falling edge of CN1-41 input signal.
2
Active on the falling edge of CN1-42 input signal.
3
Active on the falling edge of CN1-43 input signal.
4
Active on the falling edge of CN1-44 input signal.
5
Active on the falling edge of CN1-45 input signal.
6
Active on the falling edge of CN1-46 input signal.
7
Reserved (Do not change.)
8
Sets signal OFF.
9
Active on the rising edge of CN1-40 input signal.
A
Active on the rising edge of CN1-41 input signal.
B
Active on the rising edge of CN1-42 input signal.
C
Active on the rising edge of CN1-43 input signal.
D
Active on the rising edge of CN1-44 input signal.
E
Active on the rising edge of CN1-45 input signal.
F
Active on the rising edge of CN1-46 input signal.
/SPD-A Signal Mapping
0 to F Same as /SPD-D
/SPD-B Signal Mapping
0 to F Same as /SPD-D
/C-SEL Signal Mapping (Control mode change when ON (L-level))
0 to F Same as /SPD-D
Setting
Factory
Units
Range
Setting
8888
When
Classification
Enabled
After restart
Setup
(Refer to 5.6.1)
(Refer to 5.6.1)
(Refer to 5.6.1)
(Refer to 5.7.1)
Reference