Clearing Alarm History (Fn006) - YASKAWA SGMJV User Manual

Ac ?-v series
Hide thumbs Also See for SGMJV:
Table of Contents

Advertisement

7.7

Clearing Alarm History (Fn006)

The clear alarm history function deletes all of the alarm history recorded in the SERVOPACK.
Note: The alarm history can be deleted only with this function. The alarm history is not deleted when the
alarm reset is executed or the main circuit power supply of the SERVOPACK is turned OFF.
Follow the steps below to clear the alarm history.
Display after
Step
Operation
1
2
3
4
Display blinks
5
6
Keys
Press the MODE/SET Key to select the utility function
mode.
MODE/SET
DATA/
Press the UP or DOWN Key to select Fn006.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second.
The display shown on the left appears.
Note: When "no-oP" blinks for approximately one second,
the write prohibited setting is set in Fn010. Change
MODE/SET
DATA/
the setting in Fn010, and press the key again after
enabling writing. (Refer to 7.12.)
Press the MODE/SET Key to clear the alarm history.
The display shown on the left blinks for about one second
when the data is cleared.
MODE/SET
DATA/
The display changes from "donE" to the display shown on
the left.
Press the DATA/SHIFT Key for approximately one second.
"Fn006" is displayed again.
MODE/SET
DATA/

7.7 Clearing Alarm History (Fn006)