3.7.2 Precautions on Connecting Noise Filter

This section describes the precautions on installing a noise filter.
(1) Noise Filter Brake Power Supply
Use the following noise filter at the brake power input for 400 W or less servomotors with holding brakes.
MODEL: FN2070-6/07 (Manufactured by SCHAFFNER Electronic.)
(2) Precautions on Using Noise Filters
Always observe the following installation and wiring instructions.
Do not put the input and output lines in the same duct or bundle them together.
Noise
Filter
Box
Noise
Filter
Box
Separate the noise filter ground wire from the output lines.
Do not accommodate the noise filter ground wire, output lines and other signal lines in the same
duct or bundle them together.
×
Noise
Filter
Box
×
Box
Box
Separate these circuits
Noise
Filter
The ground wire
can be close to
input lines.
Box
3.7 Noise Control and Measures for Harmonic Suppression
Noise
Filter
Noise
Filter
3
3-43