7.6.3

Test without a Motor

A test without a motor is used to check the operation of the host controller and peripheral
devices by simulating the operation of the Servomotor in the SERVOPACK, i.e., without actually
operating a Servomotor. This test allows you to check wiring, debug the system, and verify
parameters to shorten the time required for setup work and to prevent damage to the machine
that may result from possible malfunctions. The operation of the Servomotor can be checked
with this test regardless of whether the Servomotor is actually connected or not.
Reference
Host controller
Response
Use Pn00C = n.X to enable or disable the test without a motor.
Parameter
n.0
(default setting)
Pn00C

n.
An asterisk is displayed on the status display of the Digital Operator while a test without a
Information
motor is being executed.
Motor Information and Encoder Information
The motor and encoder information is used during tests without a motor. The source of the
information depends on the device connection status.
• Rotary Servomotor
Motor Connection
Status
Connected
Not connected
SERVOPACK
Reference
Response
Disable tests without a motor.
1
Enable tests without a motor.
Information That Is Used
Motor information
• Rated motor speed
• Maximum motor speed
Encoder information
• Encoder resolution
• Encoder type
Motor information
• Rated motor speed
• Maximum motor speed
Encoder information
• Encoder resolution
• Encoder type
7.6 Convenient Function to Use during Trial Operation
Simulates operation
without a motor.
Meaning
Source of Information
Information in the Servomotor that is connected
• Setting of Pn000 = n.X (Rotary/Linear Startup
Selection When Encoder Is Not Connected)
• Rated motor speed and maximum motor speed
The values previously saved in the SERVOPACK will
be used for the rated motor speed and maximum
motor speed.
Use the motor displays (Un020: Rated Motor Speed
and Un021: Maximum Motor Speed) to check the
values.
• Encoder resolution: Setting of Pn00C = n.X
(Encoder Resolution for Tests without a Motor)
• Encoder type: Setting of Pn00C = n.X (Encoder
Type Selection for Tests without a Motor)

7.6.3 Test without a Motor

When Enabled Classification
After restart
Setup
7
7-21