(2) Operating Procedure
Follow the steps below to set
Setting values are as follows:
P.0000
: Write permitted (Releases write prohibited mode.) [Factory setting]
"
"
P.0001
: Write prohibited (Parameters become write prohibited from the next power ON.)
"
"
Display after
Step
Operation
1
2
3
4
5
Display blinks
6
7
8
Turn OFF the power and then turn ON again to validate the setting.
write prohibited
or
write permitted.
"
"
"
Keys
Press the MODE/SET Key to select the utility function
mode.
MODE/SET
DATA/
Press the UP or DOWN Key to select Fn010.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second.
The display shown on the left appears.
MODE/SET
DATA/
Press the UP or DOWN Key to set a value:
P.0000: Write permitted (Factory setting)
P.0001: Write prohibited
MODE/SET
DATA/
Press the MODE/SET Key to register the value.
The write prohibited settings of parameters are executed.
When the value is registered, the display shown on the left
blinks for about one second.
Note: If a value other than "P.0000" and "P.0001" is set,
MODE/SET
DATA/
The display changes from "donE" to "P.000 ."
Press the DATA/SHIFT Key for approximately one second.
"Fn010" is displayed again.
MODE/SET
DATA/
7.12 Write Prohibited Setting (Fn010)
"
Operation
"Error" is displayed.
7
7-21