3.1.5 Precautions When Using the SERVOPACK with a DC Power Input

3.1.5 Precautions When Using the SERVOPACK with a DC Power Input

When using the SERVOPACK with a DC power input, set parameter Pn001.2 to 1, and pay attention to the
following items.
• Either AC or DC power can be input to the 200 V, 400 V SERVOPACKs. Always set Pn001.2 to 1 to spec-
ify a DC power input before inputting DC power. Only AC power can be input to the 100 V SERVOPACKs.
If DC power is input without changing the parameter setting, the SERVOPACK's internal elements will burn and
may cause fire or equipment damage.
• With a DC power input, time is required to discharge electricity after the main power supply is turned OFF.
A high residual voltage may remain in the SERVOPACK after the power supply is turned OFF. Be careful
not to get an electric shock.
• Install fuses on the wires if DC power is used.
• Servomotor returns a regenerated energy to the power supply. The SERVOPACK that can use a DC
power supply is not capable of processing the regenerated energy. Provide measures to process the
regenerated energy on the power supply.
• With a DC power input, connect an external inrush current limit circuit.
Failure to observe this caution may result in damage to the product.
(1) DC Power Supply Input Terminals for the Main and Control Circuits
Three-phase, 200 V
SERVOPACK model
SGDV
R70A,R90A, 1R6A,
2R8A,3R8A, 5R5A,
7R6A,120A, 180A,
200A,330A
470A, 550A, 590A, 780A
Three-phase, 400 V
SERVOPACK model
SGDV
1R9D, 3R5D, 5R4D,
8R4D, 120D, 210D,
260D, 280D, 370D
170D
3-10
WARNING
Terminal Name and Description
Main circuit plus terminal
270 to 320 VDC
B1/
B1/
Terminal Name and Description
Main circuit plus terminal
513 to 648 VDC
B1/
Main circuit minus
Control power supply
terminal
0 VDC
2
Main circuit minus
Control power supply
terminal
0 VDC
2
2
input terminal
200 to 230 VAC
L1C, L2C
L1C, L2C
input terminal
24VDC ± 15%
24 V, 0 V
24 V, 0 V