4 Trial Operation

4.6.1 Related Parameters

4.6

Test Without Motor Function

The test without motor function is used to check the operation of the host and peripheral devices by simulating
the operation of the motor in the SERVOPACK, i.e., without actually operating the motor. This function
enables checking wiring and verifying the system and parameters when errors occur while debugging the sys-
tem, thus shortening the time required for setup work and preventing damage to the equipment that may result
from possible malfunctions. The operation of the motor can be checked during performing this function
regardless of whether the motor is actually connected or not.

4.6.1 Related Parameters

The following parameters are used for the test without motor.
Parameter
n.
0
n.
1
n.
0
Pn00C
n.
1
n. 0
n. 1
Absolute encoder is only for rotational servomotors. External encoders such as encoders for fully-closed loop control
are used as incremental encoders regardless of the setting of Pn00C.2.

4.6.2 Limitations

The following functions cannot be used during the test without motor.
• Regeneration and dynamic brake operation
• Brake output signal (The brake output signal can be checked with the I/O signal monitor function of the Sig-
maWin+.)
• Items marked with "X" in the utility function table on the next page.
If the encoder cable is disconnected and then connected again during the test without motor after having
started the test with the encoder cable connected, the utility functions that can be executed are limited to:
• Items marked with " " in the "Motor not connected" column in the utility function table on the next page.
4-12
SERVOPACK
Reference
Host controller
Response
Disables the test without motor. [Factory setting]
Enables the test without motor.
Sets 13 bits as encoder resolution for the test without motor.
[Factory setting]
Sets 20 bits as encoder resolution for the test without motor.
Sets incremental encoder as encoder type for the test without motor.
[Factory setting]
*
Sets absolute encoder
as encoder type for the test without motor.
Simulates the operation
Reference
without motor.
Response
Meaning
When
Classification
Enabled
After restart
Setup

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgdvSgmavSgmpsSgmgvSgmcs

Table of Contents