(2) Operating Procedure
Follow the steps below to perform the gain adjustment of analog monitor output.
Display after
Step
Operation
1
2
3
4
5
6
7
8
7.9 Gain Adjustment of Analog Monitor Output (Fn00D)
Keys
Press the MODE/SET Key to select the utility function
mode.
MODE/SET
DATA/
Press the UP or DOWN Key to select Fn00D.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second.
The display shown on the left appears.
Note: When "no-oP" blinks for approximately one second,
the write prohibited setting is set in Fn010. Change
MODE/SET
DATA/
the setting in Fn010, and press the key again after
enabling writing. (Refer to 7.12.)
Press the MODE/SET Key to select channel-1 or channel-2
monitor output.
MODE/SET
DATA/
Press the DATA/SHIFT Key for less than one second. Gain
adjustment data will be displayed as shown on the left.
MODE/SET
DATA/
Press the UP or DOWN Key to change the data. This com-
pletes gain adjustment of the analog monitor output.
MODE/SET
DATA/
Press the DATA/SHIFT Key for less than one second. The
analog monitor output channel is displayed as shown on the
left.
To adjust a different channel, switch the monitor channel
MODE/SET
DATA/
using steps 4 through 6.
Press the DATA/SHIFT Key for approximately one second.
"Fn00D" is displayed again.
MODE/SET
DATA/
Operation
7
7-17