7 Utility Functions (Fn
Step
4
5
6
(2) Related Parameters
Use the following parameters as required.
Pn311
Pn312
Note: Pn312 is set by the vibration detection level, so it is not necessary to adjust it.
7-26
)
Display after
Operation
MODE/SET
Display blinks
MODE/SET
MODE/SET
Vibration Detection Sensibility
Setting Range
Setting Unit
50 to 500
Vibration Detection Level
Setting Range
Setting Unit
0 to 5000
Keys
Press the MODE/SET Key for approximately one second
again. The display shown on the left will flash and the
vibration level will be detected and refreshed. This will con-
tinue until the MODE/SET Key is pressed again.
Notes:
• Operate the SERVOPACK with the references that will
DATA/
be used for actual operation.
• If the servomotor is rotating at 10% or less of the maxi-
mum speed, "Error" will be displayed.
Press the MODE/SET Key again at a suitable time to com-
plete vibration detection and refreshing the setting. This
will enable the setting. If the setting has been completed
normally, "donE" will be displayed. If there was a setting
DATA/
failure, "Error" will be displayed.
Press the DATA/SHIFT Key for approximately one second.
"Fn01b" is displayed again.
DATA/
Speed
Factory Setting
1%
100
Speed
Factory Setting
-1
50
1 min
Operation
Position
 
Torque
Classification
When Enabled
Immediately
Position
 
Torque
Classification
When Enabled
Immediately
Tuning
Tuning

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgdvSgmavSgmpsSgmgvSgmcs

Table of Contents