1 Outline
1.5.2 Connecting to SGDV-
1.5.2 Connecting to SGDV-
Molded-case
circuit breaker
(MCCB)
Protects the power supply
line by shutting the
circuit OFF when
overcurrent is
detected.
Noise filter
Used to eliminate
external noise from
the power line.
200 VAC
Brake power supply *
Used for a servomotor
with a brake.
Magnetic contactor
Turns the brake power supply
ON and OFF.
Install a surge absorber.
∗1. Use a 24 VDC power supply. (not included)
∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.6 Connecting Regenerative Resis-
tors.
1-16
A01A SERVOPACK
Power supply
Three-phase 200 VAC
R S T
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
Regenerative
resistor
*
2
1
SGMJV/SGMAV/SGMPS/
SGMGV/SGMSV
Servomotor
A01A SERVOPACK
SGDV-
A01A
SERVOPACK
Connection cable
for digital operator
Connection cable
for personal computer
I/O signal cable
Battery case
(when an absolute
encoder is used.)
Motor main
circuit cable
Digital
operator
Personal
computer
Host controller
When not using the safety function,
use the SERVOPACK with the safety
function jumper connector
(JZSP-CVH05-E, provided as an
accessory) inserted.
When using the safety function,
insert a connection cable specifically
for the safety function.
Safety function
devices
Encoder cable