Alarm Cards
Table 10-2. ALR 4+4 Card Option Settings and Defaults
Parameter
SWITCH
ACT ON
SENSOR
TRIG ON
SWITCH
The Switch setting indicates that the outbound alarm switch is actv (on) or stdby (off).
ACT ON
The Act On parameter defines the type of system alarm that will cause the switch to trigger.
Program each alarm switch to trigger on minor (information and minor) alarms, major (major
and critical) alarms, or any alarm message.
SENSOR
The Sensor setting indicates the inbound alarm sensor is actv (on) or stdby (off).
TRIG ON
The Trigger On parameter defines if the sensor should report an external alarm upon sensing
the opening (open) or the closure (close) of the C-form contact to which it is connected.
MAJOR =
The Major = accumulation register shows the current number of reported alarms designated
as Major or Critical.
MINOR =
The Minor = accumulation register shows the current number of reported alarms designated
as Minor or Informational.
System Cards
Alarm Card User Screens and Settings
User Options
stdby
actv
minor
major
any
stdby
actv
close
open
Default
stdby
minor
stdby
close
10-5