OCU-DP Card User Screens and Settings
OCSES
The Output Consecutive Severely Errored Seconds (OCSES) field is triggered by the
occurrence of ten consecutive Output Severely Errored Seconds. Once triggered, the OCSES
field will increment by one for each elapsed second until the system logs ten consecutive that
are not severely errored. This field only applies if the error correction method selected is BCH.
Since this is an information-only field, there are no user-selectable parameters.

17.3.3 Test Screen

Pressing "t" (Test) in the OCU-DP Card Main Screen will bring up the Test Screen shown in
Figure 17-10
between a single OCU-DP card and data test equipment at a remote site.
17-14
. From this screen, you can create test situations between OCU-DP cards, or
4
Figure 17-10.Typical OCU-DP Card Test Screen