OCU-DP Card
OSS
The Out of Synchronization Seconds (OSS) field shows the number of seconds that the
OCU-DP BERT has been out of synchronization. Since this is an information-only field, there
are no user-selectable parameters.
BER
The Bit Error Rate (BER) field shows the rate at which errors are being logged. The system
calculates BER by dividing the number of bit errors (BE) by the total number of bits
transmitted during the test. Since this is an information-only field, there are no user-selectable
parameters.
ELAP
The Elapsed time setting shows the running tally of the total number of seconds during the
test. Since this is an information-only field, there are no user-selectable parameters.
LB ST
The Loopback State (LB STATE) field indicates the local loopback selected on the main
screen for this port. This field will show off, ta, or net. Since this is an information-only field,
there are no user-selectable parameters.
4W DDS
The 4-wire DDS setting shows if the 4-wire interface is both present and operational. The field
will show norm if the interface is connected or nos for No Signal. Since this is an
information-only field, there are no user-selectable parameters.
Data Cards
OCU-DP Card User Screens and Settings