Continuous operation interrupt function

During positioning control, the control can be interrupted during continuous positioning control and continuous path control
(continuous operation interrupt function). When "continuous operation interruption" is execution, the control will stop when the
operation of the positioning data being executed ends. To execute continuous operation interruption, set "1: Continuous
operation interrupt request" for "[Cd.18] Interrupt request during continuous operation".
Operation during continuous operation interruption
When the stop command is ON
V
Stop command
Start
Positioning data No.10
When "1" is set in [Cd.18]
V
When "1" is set in [Cd.18]
Start
Positioning data No.10
7 CONTROL SUB FUNCTIONS
258
7.8 Functions Related to Stop
ON
Stop process when stop command turns ON
Positioning data No.11
ON
Stop process at continuous operation interrupt request
Positioning data No.11
Positioning data No.12
Positioning data No.12
t