24
:POWer Commands
:POWer:SIGNals:SOURce:VOLTage<i>
Command Syntax
:POWer:SIGNals:SOURce:VOLTage<i> <source>
<i> ::= 1, 2 in NR1 format
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels) in NR1 format
The :POWer:SIGNals:SOURce:VOLTage<i> command specifies the first, and
perhaps second, voltage source channel to be used in the power analysis.
Query Syntax
:POWer:SIGNals:SOURce:VOLTage<i>?
The :POWer:SIGNals:SOURce:VOLTage<i> query returns the voltage source
channel setting.
Return Format
<source><NL>
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels) in NR1 format
See Also
582
(see
page
1138)
":POWer:SIGNals:AUTosetup"
":POWer:SIGNals:CYCLes:HARMonics"
":POWer:SIGNals:CYCLes:QUALity"
":POWer:SIGNals:DURation:EFFiciency"
":POWer:SIGNals:DURation:MODulation"
":POWer:SIGNals:DURation:ONOFf:OFF"
":POWer:SIGNals:DURation:ONOFf:ON"
":POWer:SIGNals:DURation:RIPPle"
":POWer:SIGNals:DURation:TRANsient"
":POWer:SIGNals:IEXPected"
":POWer:SIGNals:OVERshoot"
":POWer:SIGNals:VMAXimum:INRush"
":POWer:SIGNals:VMAXimum:ONOFf:OFF"
":POWer:SIGNals:VMAXimum:ONOFf:ON"
":POWer:SIGNals:VSTeady:ONOFf:OFF"
":POWer:SIGNals:VSTeady:ONOFf:ON"
":POWer:SIGNals:VSTeady:TRANsient"
":POWer:SIGNals:SOURce:CURRent<i>"
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
on page 564
on page 565
on page 566
on page 567
on page 568
on page 569
on page 570
on page 571
on page 572
on page 573
on page 574
on page 575
on page 576
on page 577
on page 578
on page 579
on page 580
on page 581

Advertisement

Table of Contents
loading

Table of Contents