:POWer:SIGNals:VSTeady:ONOFf:OFF

Command Syntax
:POWer:SIGNals:VSTeady:ONOFf:OFF <value>[suffix]
<value> ::= Expected steady state output Voltage value in NR3 format
[suffix] ::= {V | mV}
The :POWer:SIGNals:VSTeady:ONOFf:OFF command specifies the expected
steady state output DC voltage of the power supply for turn off analysis.
Query Syntax
:POWer:SIGNals:VSTeady:ONOFf:OFF?
The :POWer:SIGNals:VSTeady:ONOFf:OFF query returns the expected steady
state voltage setting.
Return Format
<value><NL>
<value> ::= Expected steady state output Voltage value in NR3 format